91精品久久久久_国产精品亚洲一区二区麻豆_无码精品人妻一区二区三区AV免费在线观看免费网站看在线_精品国产免费久久久久_久久综合久久久久

螺柱焊現(xiàn)場(chǎng)故障代碼與報(bào)警

2022-10-28 16:39:00
孫輝
原創(chuàng)
7392

welding is not permitted.

解釋: 啟動(dòng)焊接信號(hào)后無(wú)接觸信號(hào),導(dǎo)致無(wú)法焊接

Cause: ? No stud in collet.

原因:  夾套里沒(méi)有焊釘

? Feeder without weld studs.

送料器里沒(méi)有焊釘

? Stabilizer incorrectly set or contaminated.

支撐腳或噴嘴調(diào)整不當(dāng)或太臟

? Weld circuit interrupted.

焊接回路中斷

? Weld head fault (i.e. weld head got jammed).

焊頭故障(例如:焊頭被卡住了)

? Collet defective.

夾持器損壞了

Remedy: ? Remove loading fault.

措施: 排除送釘故障

? Check adjusting of stabilizer.

檢查支撐腳或噴嘴的調(diào)整狀態(tài)

? Check welding circuit.

檢查焊接回路

? Stud feeding.

送一次釘

? Repeat weld cycle.

重復(fù)一次焊接

? Replace collet.

更換夾持器

? Notify service engineer!

專業(yè)人員處理

                                                                                                                        

Fault 3: “Weld tool not in back position“

故障 3 :焊頭沒(méi)有在焊接位置

Explanation: Proximity switch for back position not configured, defective or power supply missing.

解釋:焊接位置的接近開(kāi)關(guān)沒(méi)有被蓋住或接近開(kāi)關(guān)被損壞或者沒(méi)有電壓

Cause: ? Drop in compressed-air supply.

原因: 壓縮空氣供應(yīng)氣壓不足

? Cable package defective.

管線總成損壞

? Monitoring time after welding was exceeded.

焊接之后的檢測(cè)時(shí)間超差

? Weld head defective.

焊頭損壞

? Feeder defective.

送料器損壞

? Collet welded to work surface.

把夾持器焊在工件表面了

Remedy: ? Check compressed air.

措施:  檢查壓縮空氣供應(yīng)裝置

? Check cable package.

檢查管線總成

? Check weld head - slide rail motion.

檢查焊頭運(yùn)動(dòng)滑軌

? Check or replace weld head.

檢查或更換焊頭

? Check feeder.

檢查送料器

? Check feeder fuses F1-F3.

檢查送料器保險(xiǎn)絲F1-F3

? Reset fault.

故障復(fù)位

? Replace collet.

更換夾持器

? Notify service engineer!

專業(yè)人員處理

                                                                 

Fault 5: “Weld procedure sequence fault“

故障 5 :焊接程序順序故障

Explanation: Due to a malfunction the weld sequence is not terminated correctly.

解釋:由于一個(gè)錯(cuò)誤功能使焊接過(guò)程沒(méi)有按照程序進(jìn)行到底

Cause: ? Feeder or SMPS malfunction.

原因:  送料器或電源故障

Remedy: ? Reset fault.

措施:  故障復(fù)位

? Check welding (if necessary repeat welding).

檢查焊接(重新焊接)

? Notify service engineer!

專業(yè)人員處理

                                                                                                                        

Fault 6: “Program no selected“

故障 6 缺少程序

Explanation: The weld unit does not detect any program number.

解釋: 焊接單元不識(shí)別程序號(hào)碼

Cause: ? Program no. is 0.

原因: 程序號(hào)碼為0

? Transfer signal has not been set.

沒(méi)有設(shè)置接受信號(hào)

? Data line defective.

數(shù)據(jù)線被損壞了

Remedy: ? Customer interface (or interface program) must be verified.

措施: 檢查用戶接口(或接口程序)是否編寫(xiě)

? Notify service engineer!

專業(yè)人員處理

                                                                                                                       

Fault 7: “Program not active“

故障 7 程序沒(méi)有激活

Explanation: The selected weld program is not active and therefore cannot be executed.

解釋: 由于被選擇的焊接程序沒(méi)有被激活,因此無(wú)法實(shí)施焊接

Cause: ? Weld unit incorrectly programmed.

原因: 焊接單元程序編寫(xiě)錯(cuò)誤

? Fault customer control.

用戶控制端錯(cuò)誤

? Data line defective.

數(shù)據(jù)線被損壞了

Remedy: ? Check weld program and activate or select an active weld program.

措施:  檢查焊接程序并激活或者選擇一個(gè)已經(jīng)激活的程序

? Notify service engineer!

專業(yè)人員處理

                                                    

Fault 13: “SMPS: Lift fault“

故障 13   電源:沒(méi)有拉弧

Explanation: Weld unit is unable to identify lift via measurement lines.

解釋:焊機(jī)通過(guò)它的測(cè)量線不能確定拉弧過(guò)程

Cause: ? Incorrectly sequence of lift movement.

原因: 拉弧過(guò)程的順序不正確

? Weld conditions prohibit lift.

焊接條件阻礙了拉弧

? Cable package defective.

管線總成損壞

? Weld head defective.

焊頭被損壞

? Defective feeder.

送料器被損壞

? Internal process cycle fault.

設(shè)備內(nèi)部運(yùn)行故障

Remedy: ? Check weld conditions.

措施: 檢查焊接條件

? Check weld head.

檢查焊頭

? Check feeder.

檢查送料器

? Stud feeding.

送一次釘

? Check feeder connection.

檢查送料器連接線

? Repeat weld cycle.

重復(fù)一次焊接

? Forced WC.

啟動(dòng)焊接完成信號(hào)

? Notify service engineer!

專業(yè)人員處理

                                                           

Fault 15: “Drop down timeout“

故障 15 下落時(shí)間超時(shí)

Explanation: Max. drop time was exceeded and welding was stopped.

解釋: 下落時(shí)間超出最大允許值,焊接被中斷

Cause: ? Air gap incorrectly adjusted.

原因: 間隙調(diào)整錯(cuò)誤

? Weld circuit resistance too high.

焊接回路電阻過(guò)高

? Measurement line-ground missing.

沒(méi)有連接地線測(cè)量線

? SKK / PK defective.

自動(dòng)焊頭或焊槍損壞

Remedy: ? Reset fault.

措施: 故障復(fù)位

? check measurement line (if necessary, reduce weld circuit resistance)

檢查測(cè)量線(降低焊接回路電阻值)

? Check setting of SKK- / PK.

檢查自動(dòng)焊頭或焊槍狀態(tài)

? Notify service engineer!

專業(yè)人員處理

                                                                                                                       

Fault 16: “Open circuit, no arc“

故障 16 空載焊接

Explanation: Extinguishing of the arc during weld, resp. the weld current is below I =80A.

解釋: 焊接過(guò)程中拉弧被斷開(kāi),或焊接回路電流小于80A

Cause: ? Air gap too large.

原因: 間隙過(guò)大

? Gun was removed at the beginning of the weld.

焊槍在開(kāi)始焊接時(shí)被提起

? Extremely impure work surface.

焊接表面油污太多

? Fault SMPS.

電源故障

Remedy: ? Repeat weld cycle.

措施: 重復(fù)一次焊接

? Stud feeding.

送一次釘

? Check adjusting of the weld gun.

檢查焊槍的調(diào)整

? Check welding conditions.

檢查焊接條件

? Check work piece conditions.

檢查工件表面

? Notify service engineer!

專業(yè)人員處理

                                                                                                                    

Fault 17: “Measurement line broken“

故障 17 測(cè)量線中斷

Explanation: Measurement line signal not any longer detected.

解釋: 測(cè)量線信號(hào)沒(méi)有被捕捉到

Cause: ? Measurement line broken or incorrectly connected.

原因: 測(cè)量線損壞或連接錯(cuò)誤

? Reversed measurement line-ground and measurement line.

地線測(cè)量線和測(cè)量線接反了

? SOW power failure.

和工件的接觸電壓中斷

? Weld line interrupted.

焊接電纜中斷

Remedy: ? Check fuses on front panel.

措施: 檢查面板上的保險(xiǎn)絲

? Reset fault.

故障復(fù)位

? Check welding cable.

檢查焊接線

? Check measuring line.

檢查測(cè)量線

? Check ground- measurement line

檢查地線測(cè)量線.

? Check feeder fuses.

檢查送料器的保險(xiǎn)絲

? Notify service engineer!

專業(yè)人員處理

                                                        

Fault 23: “Handgun sequence not followed“

故障 23 手槍焊接啟動(dòng)條件

Explanation: Correct sequence when welding with a gun (PK/PLM) was not observed.

解釋:  在用手槍焊接時(shí)沒(méi)有遵守正確的焊接順序

Cause: ? Angularity switch by-passed or incorrectly adjusted.

原因: 角度開(kāi)關(guān)被橋接或調(diào)整錯(cuò)誤

? Trigger start by-passed.

啟動(dòng)開(kāi)關(guān)被橋接

? Correct sequence "SOW-ANG-START" not observed.

沒(méi)有遵守SOW(接觸信號(hào))-WS(角度開(kāi)關(guān))- START(焊接)的焊接順序

Remedy: ? Observe sequence "SOW-ANG-START".

措施:  遵守SOW(接觸信號(hào))-WS(角度開(kāi)關(guān))- START(焊接)的焊接順序

? Check PK for correct setting of angularity.

檢查角度開(kāi)關(guān)的調(diào)整情況

? Release trigger and restart.

松開(kāi)啟動(dòng)開(kāi)關(guān)并重新啟動(dòng)

? Notify service engineer!

專業(yè)人員處理

                                    

Fault 25: “Wrong stud loaded“

故障 25 焊釘輸送錯(cuò)誤

Explanation: The supplied stud is not the specified stud required by unit control.

解釋: 所提供的焊釘不是焊機(jī)指定的焊釘

Cause: ? The weld unit identified an incorrect stud in the weld head via the lift measuring system or the stud verification test.

原因:  焊機(jī)只識(shí)別通過(guò)拉弧測(cè)量系統(tǒng)或者通過(guò)焊釘檢驗(yàn)的焊釘?shù)暮割^   

Remedy: ? Reset fault.

措施:  故障復(fù)位

? Repeat stud feeding.

重新送一次釘

? Verify correct stud length in the feeder.

檢驗(yàn)送料器里焊釘?shù)拈L(zhǎng)度

? Check programming.

檢查程序

                                                                                                                      

Fault 30: “Weld out of tolerance”

故障 30 焊接參數(shù)超差

Explanation: Collective fault for the exceeded tolerances.

解釋:  一般性超差

Cause: ? The following tolerances are out of parameter: weld current, weld time, Vp, Vw, Pen, Varc peak, Varc drop or weld energy.

原因: 超出公差的參數(shù):焊接電流,焊接時(shí)間,拉弧電壓,焊接電壓,焊接深度,電壓峰值,電壓降或焊接能量

? Defective SMPS or welding tool.

電源或焊接工具損壞

Remedy: ? Reset fault.

措施: 故障復(fù)位

? Check tolerances.

檢查公差設(shè)定值

? Check weld circuit and weld conditions.

檢查焊接電流和焊接條件

? Check SMPS and welding tool.

檢查電源和焊接工具

                                   

Fault 100: “Feeder: No power to aux. supply“

故障 100 送料器:沒(méi)有電壓

Explanation: The feeder identifies no voltage supply.

解釋: 送料器沒(méi)有電壓供應(yīng)

Cause: ? Defective feeder fuse.

原因: 送料器保險(xiǎn)絲損壞

? Defective feeder.

送料器損壞

Remedy: ? Replace feeder fuse.

措施: 更換送料器保險(xiǎn)絲

? Check feeder.

檢查送料器

? Notify service engineer!

專業(yè)人員處理

                                     

ault 102: “Feeder: Feed rail not filled in time“

故障 102 送料器:焊釘傳送錯(cuò)誤

Explanation: Filling of the rail way is not ensured.

解釋: 焊釘傳送過(guò)程中出現(xiàn)故障

Cause: ? Sufficient stud level in the separating drum not reached.

原因: 焊釘卡在了滑道上

? Mechanical defect of the escapement rails

滑道上有機(jī)械故障

? Wrong adjusting on the stud inlet dish.

焊釘口調(diào)整錯(cuò)誤

? Wrong adjusted or defective proximity switch "Min".

最小接近開(kāi)關(guān)調(diào)整錯(cuò)誤或損壞

Remedy: ? Check adjusting.

措施: 檢查送料器調(diào)整

? Replenish weld studs.

加滿焊釘

? Remove blockage.

清除滑道上焊釘

? Adjust proximity switch or/and replace.

調(diào)整接近開(kāi)關(guān)或更換

? Notify service engineer!

專業(yè)人員處理

                                       

Fault 106: “Feeder: Feed tube locking switch open“

故障 106 送料器:送料管被鎖緊

Explanation: The signal for feed hose locking at the stud feeder is not configured.

解釋: 送料器鎖緊信號(hào)開(kāi)關(guān)沒(méi)有被蓋上

Cause: ? Feed tube not connected (gun).

原因: 送料管沒(méi)有連接

? No bridge for feed tube locking (head).

送料管鎖緊開(kāi)關(guān)沒(méi)有連上

? Defective cable package.

管線總成損壞

? Defective fuse F5 on PCB ETF CPU E510.

中央處理器E510電路板保險(xiǎn)絲F5損壞

Remedy: ? Connecting feed tube.

措施: 連接送料管

? Check locking switch.

檢查緊鎖開(kāi)關(guān)

? Check cable package.

檢查管線總成

? Replace fuse.

更換保險(xiǎn)絲

? Notify service engineer!

專業(yè)人員處理

                                   

Fault 109: “Feeder: Feed cycle timeout“

故障 109 送料器:送料循環(huán)超時(shí)

Explanation: The weld unit indicates an incorrectly performed feed cycle.

解釋: 焊機(jī)顯示一個(gè)錯(cuò)誤的送料循環(huán)

Cause: ? The feeder does not terminate a feed cycle in the maximum

monitoring time.

原因: 送料器沒(méi)有把送料循環(huán)鎖定在最大的監(jiān)控時(shí)間內(nèi)

Remedy: ? Check feeder.

措施: 檢查送料器

? Repeat stud feeding.

重復(fù)一次焊接

? Notify service engineer!

專業(yè)人員處理

                                             

Fault 118: “Feeder: +5V Keypad not detected“

故障 118 :送料器:控制面板沒(méi)有 +5V 電壓供應(yīng)

Explanation: The voltage supply 5V for the keypad communication is missing.

解釋: 控制面板通信的+5V電壓沒(méi)有

Cause: ? Defective fuse F3 on PCB ETF CPU E510.

原因: 中央處理器E510電路板保險(xiǎn)絲F3損壞

? Defective optocoupler on the PCB ETF CPU E510.

E510電路板上的光耦合器損壞

Remedy: ? Replace fuse.

措施: 更換保險(xiǎn)絲

? Replace PCB ETF CPU E510.

更換E510電路板

? Notify service engineer!

專業(yè)人員處理

                                                                                                                    

Fault 119: “Feeder: LM / Solenoid under voltage“

故障 119 送料器:自動(dòng)焊槍 / 電磁閥不足

Explanation: The voltage supply for the linear motor / solenoid is less than 90 Volt

解釋: 直流電機(jī)/電磁閥的供電電壓低于90V

Cause: ? Defective fuse F2 on ETF PCB Amplifier E 512.

原因: 放大器E512     電路板保險(xiǎn)絲F2損壞

? Defective ETF PCB amplifier E 512.

放大器E512電路板損壞

Remedy: ? Replace fuse F2.

措施: 更換保險(xiǎn)絲F2

? Replace ETF PCB Amplifier E 512.

更換放大器E512電路板

? Notify service engineer!

專業(yè)人員處理

                                           

Fault 121: “Feeder: LM/Solenoid over voltage“

故障 121 :送料器:自動(dòng)焊槍 / 電磁閥電壓超出

Explanation: The voltage supply for pcb E 512 is out of the tolerance range.

解釋: 給電路板E512供電的電壓超出公差范圍

Cause: ? Transformer wrong connected.

原因: 轉(zhuǎn)換器連接錯(cuò)誤

? Defective transformer.

轉(zhuǎn)換器損壞

Remedy: ? Check connection transformer.

措施: 檢查轉(zhuǎn)換器連接

? Exchange transformer.

更換轉(zhuǎn)換器

? Notify service engineer!

專業(yè)人員處理

                                                                                                                    

Fault 122: “LM/Solenoid not detected“

故障 122   自動(dòng)焊槍 / 電磁閥故障

Explanation: The connected welding tool on the feeder has not linear motor or solenoid.

解釋: 同送料器連接的焊接工具不是直線電機(jī)或電磁閥

Cause: ? No welding tool connected.

原因: 沒(méi)有連接焊接工具

? Defective cable package.

管線總成損壞

Remedy: ? Connect weld tool.

措施: 連接焊接工具

? Check cable package.

檢查管線總成

? Notify service engineer!

專業(yè)人員處理

                          

Fault 167: “Feeder: +5V not detected“

故障 167 送料器: +5V 檢測(cè)電壓缺失

Explanation: The voltage supply +5V for the measurement stretch length is missing.

解釋: 測(cè)量拉伸長(zhǎng)度的+5V電壓缺失

Cause: ? Defective cable package.

原因: 管線總成損壞

? Defective PCB in the weld head.

焊頭里的電路板損壞

? Defective optocoupler on the ETF CPU E510.

E510里的光耦合器損壞

Remedy: ? Check cable package.

措施: 檢查管線總成

? Check PCB in the weld head.

檢查焊頭里的電路板

? Replace PCB ETF CPU E510.

更換E510電路板

? Notify service engineer!

專業(yè)人員處理

評(píng)論列表
2024-02-27 17:37:20
電源故障異常是什么
1/1
發(fā)表評(píng)論
拆信。(打一城市名)?(答案:開(kāi)封)
評(píng)論通過(guò)審核后顯示。
聯(lián)系我們
聯(lián)系人: 韓玉琦
電話: 0755-26013200/26013464
傳真: 0755-26013188
Email: saw@sawchina.cn
QQ: 2280915288
微信: 18682260315
旺旺: szhbkj
地址: 東莞市鳳崗鎮(zhèn)東深路鳳崗段206號(hào)天安深創(chuàng)谷W2棟誠(chéng)信大廈21樓
  • 在線客服
  • 關(guān)注微信
    • 業(yè)務(wù)咨詢
    • 人才招聘
    • 售后咨詢
  • 掃一掃關(guān)注微信
  鴻栢科技
  深圳市鴻栢科技實(shí)業(yè)有限公司
移動(dòng)訪問(wèn)